OptiMOS™ Power Stages CPU · GPU · ASIC Power Multiphase Regulation

The TDA21490 and TDA21590 are integrated power stages from Infineon Technologies. Each combines a synchronous buck gate driver with high-side and low-side MOSFETs in a compact package.

They are intended for low-voltage, high-current power conversion, including processor, graphics, and other demanding computing rails. A compatible controller, external inductor, capacitors, and an appropriate PCB complete the regulator.

Although the devices share a similar package footprint and both appear in the 90 A product category, their electrical interfaces and current-rating descriptions differ. These differences matter when selecting a controller, designing current sensing, or evaluating a replacement.

This guide compares the published specifications and explains their practical implications. Numerical examples are illustrative calculations unless explicitly identified as manufacturer specifications.

1. TDA21490 and TDA21590 Specification Comparison

The table follows the cited Infineon data sheets. Values describe the devices under their documented conditions and do not guarantee operation at every possible combination of voltage, current, frequency, and temperature.

Parameter TDA21490 TDA21590
Device architecture Driver with high-side and low-side MOSFETs Driver, MOSFETs, and active-diode structure
Power input range 4.25–16 V 4.25–16 V
VCC and VDRV 4.25–5.5 V 4.25–5.5 V
Published output-voltage range 0.25–5.5 V 0.225–5.5 V at VIN = 12 V
Published current capability 90 A peak; 70 A DC 90 A capability; operating and thermal limits apply
Switching operation Up to 1.5 MHz Up to 1.5 MHz
Current-reporting scale 5 mV/A relative to REFIN 5 µA/A through the IMON network
Temperature-reporting slope 8 mV/°C 8 mV/°C
PWM interface 3.3 V tri-state compatible 3.3 V tri-state compatible
Data-sheet package dimensions 5 × 6 × 1 mm PQFN 5 × 6 × 0.9 mm PQFN
Orderable part number TDA21490AUMA1 TDA21590AUMA1

A shared footprint size does not establish a shared pin function or electrical interface. The current-rating descriptions also require separate interpretation rather than a direct comparison of headline numbers.

2. What an Integrated Power Stage Does

In a synchronous buck converter, the high-side MOSFET transfers energy from the input, while the low-side MOSFET provides the complementary current path. The driver controls these devices according to the external controller’s PWM command.

Combining the driver and MOSFETs reduces some interconnections and allows their switching behavior to be designed as a coordinated stage.

Neither device integrates the output inductor. An external inductor, input capacitors, output capacitors, controller, and suitable sensing arrangement are required to build the complete regulator.

The SW pins are the switching node, not a finished regulated output. The regulated rail is established after the inductor and output network.

This distinction separates these devices from power modules that integrate inductors, and from standalone regulators containing their own complete control loop.

Output-voltage range therefore describes supported converter operation. It is not a set of internally selectable fixed outputs.

3. TDA21490: Practical Characteristics

The TDA21490 combines temperature-compensated current reporting with programmable cycle-by-cycle overcurrent protection and an analog temperature/fault output.

Its data sheet explicitly separates peak current capability from DC capability. This is important when estimating phase count or comparing it with another device marketed in the same current class.

A short current excursion and a sustained thermal load are different operating conditions. Design analysis must consider pulse duration, repetition, junction temperature, and the available heat path.

The voltage-scaled current signal can suit controllers designed for that interface, but the reference voltage and signal routing must match the data-sheet requirements.

The device is relevant to processor and other high-current rails when the controller, power stage, magnetic component, and cooling arrangement form a validated combination.

4. TDA21590: Practical Characteristics

The TDA21590 uses a current-reporting interface and includes enhanced fault identification through the current-monitor and temperature/fault signals.

Its active-diode structure is intended to improve the low-side conduction behavior associated with switching intervals. The overall efficiency benefit still depends on operating voltage, frequency, current, and temperature.

The published current capability should be evaluated using the operating conditions and thermal derating information. It is not a promise that every PCB can sustain that current continuously.

The data sheet also describes deep-sleep operation, bootstrap replenishment, and controller-coordinated transient support.

For selection, its sensing and fault interfaces deserve as much attention as its MOSFET performance. A controller designed for another power stage may require different circuitry or settings.

5. Current Sensing: 5 mV/A vs. 5 µA/A

This is one of the most consequential differences between the two products.

TDA21490: Voltage-Scaled Reporting

The difference between IOUT and REFIN represents current at the documented voltage gain. The controller must interpret the signal relative to the correct reference.

TDA21590: Current Reporting

IMON works with an external resistor and IMONREF arrangement to develop a current-related voltage for the controller.

For illustration, 60 A at a 5 mV/A gain corresponds to a 300 mV signal difference. A 5 µA/A reporting current at the same load is 300 µA.

For TDA21590, the data sheet recommends a 1 kΩ IMON resistor when a 5 mV/A voltage scale is required. That converts the illustrative 300 µA into 300 mV.

Matching the resulting nominal gain does not make the interfaces interchangeable. Reference behavior, output structure, fault signaling, loading, filtering, and controller limits can differ.

Also distinguish gain from accuracy. A scale factor says how the signal relates to current; it does not establish its worst-case error across temperature and operating conditions.

6. Temperature Reporting and Shared Fault Functions

Both data sheets describe an analog temperature relationship with an offset and slope. Interpreting only the slope without the offset produces an incorrect temperature estimate.

Using the documented nominal relationship, 25°C corresponds to approximately 0.8 V, while 100°C corresponds to approximately 1.4 V.

These calculations illustrate signal scaling rather than measurement accuracy. Sensor tolerance, controller conversion, grounding, and operating conditions still contribute error.

The temperature pin also participates in fault reporting. A fault-driven level should not be interpreted as an ordinary extension of the temperature curve.

For TDA21590, the controller can use combinations of temperature/fault and current-monitor behavior to distinguish fault conditions. Firmware and hardware must follow the documented identification method.

Any connection combining temperature outputs from several stages should use the supported arrangement. Do not assume arbitrary analog outputs can be tied together.

7. Controller, Bias Supply, and PWM Compatibility

A suitable PWM controller establishes the rail voltage, phase timing, current balancing, and system-level operating behavior.

Tri-state PWM compatibility includes a defined state that turns both MOSFETs off. This is different from merely sending a conventional high or low logic level.

Check thresholds, timing, minimum pulses, enable behavior, and fault interaction. Do not assume that any GPIO or arbitrary PWM source can safely operate the complete high-current converter.

The main VIN supply and the VCC/VDRV supplies serve different purposes. A nominal 12 V power input does not mean the logic or gate-driver supply pins can accept 12 V.

Bias decoupling and grounding should follow the device-specific circuit. Controller current-sense inputs must match the reporting structure and reference levels.

Neither power stage should be described as independently providing a PMBus or I²C management interface. Any digital management path belongs to the associated controller and system implementation.

8. Protection and Fault Coordination

The devices include protection related to current, temperature, bias undervoltage, bootstrap voltage, and power-stage faults.

Protection must be considered as a coordinated response between the stage and controller. A fault indication does not necessarily mean every rail shuts down in the same way.

Cycle-by-cycle current protection can limit or truncate switching activity when excessive current is detected. Its threshold is separate from the recommended continuous operating current.

For example, an overcurrent threshold above the published load capability is a fault boundary, not an additional usable current rating.

High-side short detection addresses a serious power-stage fault. The controller and complete power architecture determine the system response.

Output overvoltage supervision, rail sequencing, and host diagnostics may involve functions outside the power-stage IC. Avoid attributing every protection feature of a complete evaluation board to the stage alone.

Verify fault recovery, latching, signal levels, and restart conditions using the applicable data-sheet revision.

9. Bootstrap Replenishment, Sleep, and Load Release

The high-side gate driver uses a bootstrap supply referenced to the switching node. Its capacitor provides charge needed for high-side operation.

Bootstrap replenishment helps prevent excessive discharge under supported conditions, but it does not remove the need for the specified capacitor and connection arrangement.

Follow the device’s bootstrap-component guidance, including any input-voltage-dependent requirements. Values and routing from one device should not automatically be copied to the other.

Deep-sleep operation reduces consumption when the stage is disabled appropriately. Evaluate the complete rail’s sleep behavior, including controller consumption, leakage, and wake-up sequencing.

Both data sheets identify Body-Braking support. This is a controller-coordinated transient function, not an autonomous substitute for a correctly compensated loop or adequate output capacitance.

Test load release as carefully as load application. A low-voltage rail can violate its upper limit during overshoot even when its undershoot performance is acceptable.

10. Efficiency, Heat, and Sustainable Current

Current capability cannot be separated from thermal conditions. Conduction loss, switching loss, driver consumption, PCB resistance, and inductor loss all contribute to the implemented converter.

At a low output voltage, a large current does not necessarily imply a large output wattage. A hypothetical 0.8 V rail at 60 A supplies 48 W to its load.

If the complete converter achieved an assumed 90% efficiency at that point, total loss would be approximately 5.33 W. This is an arithmetic example, not a measured result for either stage.

Total converter loss is different from power-stage package dissipation. Some heat is generated in the inductor, capacitors, and conductors.

This distinction also matters when reading efficiency curves. The TDA21590 typical-condition section specifies exclusions such as inductor and controller losses for its plotted power-stage results.

Thermal resistance depends on the measurement configuration. A junction-to-ambient value based on a specified test board should not be applied unchanged to every design.

Validate local temperature after the system reaches thermal equilibrium. Include neighboring phases, airflow obstruction, heatsinks, and enclosure warming.

Use the actual thermal derating information to determine sustainable phase current. The highest advertised current should not be multiplied by phase count without an operating-margin analysis.

11. PCB Layout and External-Component Selection

Input Bypass Loop

Place the required ceramic capacitors close to the power input and return connections. Excessive loop inductance can increase switching overshoot and interference.

Switching Node

Keep the switching connection appropriate for current flow while limiting unnecessary coupling into sensitive signals. Follow the manufacturer’s placement and copper guidance.

Inductor Selection

Check saturation against peak current, including ripple and transients. Winding resistance and core loss affect both efficiency and temperature.

Current and Temperature Signals

Route reporting signals away from switching nodes and high-current return paths. Their reference connections are part of the measurement circuit.

Thermal Copper and Assembly

Use the exact land pattern, pad connections, solder-mask guidance, and reflow requirements. Similar external dimensions do not establish identical internal pad assignments.

When measuring switching waveforms, use a low-inductance probing arrangement. Probe pickup can create apparent ringing that leads to unnecessary circuit changes.

12. Application and Selection Directions

These stages are relevant to processor, graphics, ASIC, SoC, and other high-current rails where multiphase conversion is appropriate.

Selection should begin with the load’s voltage window, current profile, input source, and transient requirement. The controller and power stage should then be evaluated as a compatible pair.

For a hypothetical 400 A rail, using an application-qualified 50 A per phase would suggest eight phases before additional requirements are considered. This is a planning example rather than a validated design recommendation.

The sustainable per-phase target depends on cooling, frequency, conversion ratio, layout, and the load profile. It may be lower than the stage’s headline capability.

Do not infer automotive qualification from an application category on a general product webpage. Qualification must be established for the exact orderable device and intended use.

Likewise, using a stage in a memory-related regulator does not make it a complete on-DIMM DDR5 PMIC. The required control, rail architecture, and management functions must be provided by the full system.

13. Can TDA21490 and TDA21590 Be Substituted?

A replacement requires more than matching the 5 × 6 mm footprint and current category.

The current-reporting interfaces differ, and the data-sheet pin functions also contain important changes.

For example, the reviewed TDA21490 data sheet assigns pin 37 to OCSET, while the reviewed TDA21590 data sheet identifies that pin as a power-ground connection. This alone requires a schematic and land-pattern review before substitution.

Compare all pins, bias requirements, bootstrap components, current-reference behavior, fault interpretation, thermal performance, and controller settings.

A shared nominal reporting gain obtained through an external resistor does not resolve the other differences.

Approve a replacement only after the complete regulator passes the relevant electrical, transient, thermal, and fault tests.

14. Validation and Procurement Checklist

Use the complete orderable numbers TDA21490AUMA1 and TDA21590AUMA1 in purchasing records and approved bills of materials.

Confirm current lifecycle status, qualification documents, handling requirements, and the applicable package drawing for the exact item.

Before release, verify the following areas:

  • Electrical compatibility: Input, bias supplies, controller interfaces, and pin functions.
  • Power stage: Inductor, capacitors, bootstrap network, and current limits.
  • Regulation: DC accuracy, distribution loss, undershoot, overshoot, and recovery.
  • Sensing: Current gain, reference behavior, temperature scaling, and fault levels.
  • Thermal operation: Sustainable phase current under the intended cooling conditions.
  • Power transitions: Startup, shutdown, sleep, wake-up, and relevant fault recovery.
  • Production control: Approved components, assembly process, and controller configuration.

Record the PCB revision, load profile, input conditions, cooling setup, and instrument configuration with the results. This provides a reproducible baseline for future sourcing or design changes.

Choose the Stage and Controller as One Regulator System

TDA21490 and TDA21590 combine power switching, sensing, and protection in compact packages. Their practical differences extend beyond headline current ratings.

Current-reporting format, pin functions, bias circuitry, fault handling, thermal limits, and controller compatibility should guide selection. The correct choice is the one validated within the complete regulator and its intended operating environment.

Official Infineon References

FREQUENTLY ASKED QUESTIONS

TDA21490 and TDA21590: 5 Practical FAQs

1. Are these complete voltage regulators?

No. They integrate the driver and switching MOSFETs, but require an external controller, inductor, capacitors, and supporting circuitry. The switching-node connection is not a finished regulated output.

2. Does TDA21490 support 90 A continuously?

Its reviewed data sheet distinguishes 90 A peak capability from 70 A DC capability. Sustainable operation still depends on voltage conversion, frequency, temperature, and the PCB thermal environment. Do not treat the peak figure as a continuous design target.

3. What is the main current-sensing difference?

TDA21490 reports a current-related voltage relative to REFIN. TDA21590 reports a current through an external resistor arrangement. Matching the resulting nominal voltage gain does not establish identical reference, loading, or fault behavior.

4. Can TDA21590 directly replace TDA21490?

Direct replacement should not be assumed. Current reporting and pin functions differ, including the reviewed pin-37 assignment. A replacement requires schematic, layout, controller, protection, and thermal review followed by regulator validation.

5. Can VIN, VCC, and VDRV all connect to 12 V?

No. The main power-input range and the bias-supply ranges are different. VCC and VDRV are specified for the lower bias-voltage range shown in the data sheet. Follow the device-specific supply and decoupling circuit.

Ersa

Leda Lunardi has more than 10 years of extensive experience in electronic components and semiconductors, specializing in power devices, wide-bandgap semiconductors, advanced packaging, and reliability engineering. She possesses end-to-end expertise spanning device physics, materials R&D, process integration, and mass production. As a leading authority, she has driven key technological breakthroughs and industrialization, with extensive publications and core patents, and is highly recognized worldwide.