Texas Instruments_ADS1198CPAG

Texas Instruments
ADS1198CPAG  
Analog Front End

Texas Instruments
ADS1198CPAG
724-ADS1198CPAG
Ersa
Texas Instruments-ADS1198CPAG-datasheets-3680943.pdf
IC AFE 8 CHAN 16BIT 64TQFP
In Stock : 180

Not available to buy online? Want the lower wholesale price? Please Send RFQ to get best price, we will respond immediately

QUICK RFQ
ADD TO RFQ LIST
ersa FreeSample ersa flow
ISO9001
Quality Policy
ISO45001
ISO14001

ADS1198CPAG Description

ADS1198CPAG Description

The ADS1198CPAG from Texas Instruments is a high-performance, 16-bit, 8-channel analog front-end (AFE) designed for precision data acquisition in medical, industrial, and instrumentation applications. Housed in a 64-TQFP package, this IC integrates a low-noise programmable gain amplifier (PGA), a high-resolution delta-sigma ADC, and flexible digital interfaces. It operates with dual supply voltages (1.65V–3.6V digital, 2.7V–5.25V analog), ensuring compatibility with diverse system designs while consuming just 8.2 mW of power. The device is ROHS3 compliant, REACH unaffected, and rated for MSL 3 (168 hours), making it suitable for environmentally conscious and reliability-focused applications.

ADS1198CPAG Features

  • 16-Bit Resolution: Delivers high-accuracy signal conversion for sensitive measurements.
  • 8-Channel Input: Supports simultaneous multi-channel data acquisition, ideal for EEG/ECG systems.
  • Low Power Consumption: Optimized for battery-powered portable devices (8.2 mW typical).
  • Flexible Supply Rails: Independent analog (2.7V–5.25V) and digital (1.65V–3.6V) supplies enhance design versatility.
  • Integrated PGA: Programmable gain (1–12) improves dynamic range for low-amplitude signals.
  • Robust Compliance: Meets ROHS3, REACH, and EAR99 standards for global deployment.
  • Surface-Mount TQFP Package: Compact footprint (64-pin) suits space-constrained PCBs.

ADS1198CPAG Applications

  • Medical Diagnostics: ECG, EEG, and EMG systems benefit from its low-noise, multi-channel capability.
  • Portable Monitoring Devices: Ultra-low power extends battery life in wearable health tech.
  • Industrial Sensors: High-resolution ADC ensures precision in strain gauge or temperature measurements.
  • Test & Measurement Equipment: Multi-channel support simplifies data acquisition in lab instruments.

Conclusion of ADS1198CPAG

The ADS1198CPAG stands out as a versatile, high-performance AFE solution, combining 16-bit resolution, low-power operation, and multi-channel integration in a compact form factor. Its compliance with stringent environmental standards and suitability for medical/industrial use cases make it a preferred choice for engineers designing next-generation precision measurement systems. Texas Instruments’ robust support further ensures reliability in critical applications.

Tech Specifications

Number of Channels per Chip
Power Supply Type
Resolution (bit)
PPAP
Voltage - Supply, Analog
Product Status
Automotive
Supplier Package
Package / Case
Number of Channels
REACH Status
Maximum Operating Supply Voltage (V)
Number of Bits
EU RoHS
Moisture Sensitivity Level (MSL)
ECCN
Mounting Type
Standard Package Name
Pin Count
Mounting
Power (Watts)
Typical Supply Current (mA)
Sampling Rate (ksps)
Lead Shape
SVHC
Typical Operating Supply Voltage (V)
HTSUS
Package
Number of ADC Inputs
Category
PCB changed
HTS
ECCN (US)
Supplier Device Package
Minimum Operating Temperature (°C)
Maximum Operating Temperature (°C)
Package Height
Mfr
Interface Type
RoHS Status
Voltage - Supply, Digital
Number of ADCs
Package Length
Series
Type
Part Status
Package Width
Base Product Number
Minimum Operating Supply Voltage (V)
Unit Weight
Analog Supply Voltage
RoHS
Supply Voltage - Min
Operating Supply Current
Sampling Rate
Features
Maximum Operating Temperature
INL - Integral Nonlinearity
Supply Voltage - Max
Mounting Style
Input Type
Architecture
Reference Type
Minimum Operating Temperature
Digital Supply Voltage
Number of Converters
Moisture Sensitive
Operating Supply Voltage
SNR - Signal to Noise Ratio
Power Consumption
Pd - Power Dissipation
USHTS
Resolution

ADS1198CPAG Documents

Download datasheets and manufacturer documentation for ADS1198CPAG

Ersa Mechanical Outline Drawing       Function Diagram      
Ersa Add Cu as Alternative Bond Wire Metal for Select Devices (PDF)       Product Change Notification (PDF)      
Ersa Thermal Noise Analysis in ECG Applications       Respiration Rate Measurement Using Impedance Pneumography       Improving Common-Mode Rejection Using the Right-Leg Drive Amplifier       Heart-Rate and EKG Monitor Using the MSP430FG439 (Rev. B)       Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)       Understanding Lead-Off Detection in ECG (Rev. A)      

Shopping Guide

Payment Methods
Payment Methods include Prepayment TT (bank transfer), Western Union, and PayPal. Customers are responsible for shipping costs, bank charges, customs duties and taxes.
Shipping Rate
Shipments are made once a day around 5pm, excluding Sundays. Once shipped, the estimated delivery time is usually 5-7 business days, depending on the courier you choose.
Delivery Methods
Provide DHL, FedEx, UPS, EMS, SF Express and Registered Airmail International Delivery Service