Texas Instruments_ADS8862IDGSR

Texas Instruments
ADS8862IDGSR  
Analog to Digital Converters

Texas Instruments
ADS8862IDGSR
700-ADS8862IDGSR
Ersa
Texas Instruments-ADS8862IDGSR-datasheets-10701060.pdf
IC ADC 16BIT SAR 10VSSOP
In Stock : 10000

Not available to buy online? Want the lower wholesale price? Please Send RFQ to get best price, we will respond immediately

QUICK RFQ
ADD TO RFQ LIST
ersa FreeSample ersa flow
ISO9001
Quality Policy
ISO45001
ISO14001

ADS8862IDGSR Description

ADS8862IDGSR Description

The ADS8862IDGSR is a 16-bit, 680 ksps, microPOWER™ SAR A/D converter from Texas Instruments. This high-performance ADC is designed to meet the demands of a wide range of applications, including industrial, medical, and consumer electronics. With its 1:1 S/H:ADC ratio and external reference type, the ADS8862IDGSR offers exceptional accuracy and flexibility in signal conversion. The device is RoHS3 compliant and REACH unaffected, ensuring environmental compliance and long-term availability.

ADS8862IDGSR Features

  • 16-bit resolution for high accuracy and signal fidelity
  • 680 ksps sampling rate for fast data acquisition
  • 1:1 S/H:ADC ratio for improved signal integrity
  • External reference type for flexibility in signal conversion
  • 2.7V to 3.6V analog supply voltage range for compatibility with various power sources
  • 1.65V to 3.6V digital supply voltage range for compatibility with different digital systems
  • SAR architecture for low power consumption and high performance
  • SPI data interface for easy integration with microcontrollers and digital systems
  • Surface mount packaging for compactness and ease of assembly
  • Moisture sensitivity level 2 (MSL 2) for reliable operation in various environments
  • EAR99 ECCN for easy export compliance

ADS8862IDGSR Applications

The ADS8862IDGSR is ideal for a wide range of applications where high accuracy and fast data acquisition are required. Some specific use cases include:

  1. Industrial automation and control systems: The high-resolution ADC can be used for precise measurement and control of various process parameters, such as temperature, pressure, and flow rates.

  2. Medical equipment: The ADS8862IDGSR can be used for accurate monitoring of vital signs, such as heart rate, blood pressure, and respiration rate, in medical devices like patient monitors and diagnostic equipment.

  3. Consumer electronics: The high-speed ADC can be used for audio processing, image capture, and other applications where high-resolution signal conversion is required.

  4. Power management and energy monitoring: The ADS8862IDGSR can be used for accurate measurement of power consumption and energy usage in various electronic devices, helping to optimize energy efficiency and reduce power consumption.

Conclusion of ADS8862IDGSR

The ADS8862IDGSR is a high-performance, 16-bit SAR A/D converter from Texas Instruments that offers exceptional accuracy, flexibility, and reliability for a wide range of applications. With its 680 ksps sampling rate, 1:1 S/H:ADC ratio, and external reference type, the ADS8862IDGSR is an ideal choice for applications requiring high-resolution signal conversion and fast data acquisition. Its RoHS3 compliance and REACH unaffected status ensure long-term availability and environmental compliance, making it a reliable choice for your next project.

Tech Specifications

Configuration
Data Interface
Polarity of Input Voltage
PPAP
Voltage - Supply, Analog
Product Status
Automotive
Supplier Package
Package / Case
Signal to Noise Ratio
REACH Status
Number of Inputs
Number of Bits
EU RoHS
Sampling Rate (Per Second)
Moisture Sensitivity Level (MSL)
Operating Temperature
Full Scale Error
Architecture
Converter Type
Digital Interface Type
ECCN
Input Voltage
Mounting Type
Standard Package Name
No Missing Codes (bit)
Reference Type
Pin Count
Mounting
Number of Input Channels
Input Signal Type
Typical Power Dissipation (mW)
Lead Shape
HTSUS
Package
Resolution
Number of A/D Converters
PCB changed
HTS
ECCN (US)
Maximum Power Dissipation (mW)
Voltage Supply Source
Supplier Device Package
Single-Ended Input
Minimum Operating Temperature (°C)
Maximum Operating Temperature (°C)
Ratio - S/H:ADC
Package Height
Mfr
Sampling Rate
Integral Nonlinearity Error
Features
RoHS Status
Input Type
Voltage - Supply, Digital
Number of ADCs
Sample and Hold
Package Length
Series
Part Status
Package Width
Voltage Reference
Base Product Number
Unit Weight
Analog Supply Voltage
RoHS
Supply Voltage - Min
Number of Channels
Maximum Operating Temperature
Supply Voltage - Max
Interface Type
Mounting Style
SINAD - Signal to Noise and Distortion Ratio
Minimum Operating Temperature
Digital Supply Voltage
Moisture Sensitive
Operating Supply Voltage
SNR - Signal to Noise Ratio
Power Consumption
USHTS

ADS8862IDGSR Documents

Download datasheets and manufacturer documentation for ADS8862IDGSR

Ersa ADS8862      
Ersa ADS8862      

Shopping Guide

Payment Methods
Payment Methods include Prepayment TT (bank transfer), Western Union, and PayPal. Customers are responsible for shipping costs, bank charges, customs duties and taxes.
Shipping Rate
Shipments are made once a day around 5pm, excluding Sundays. Once shipped, the estimated delivery time is usually 5-7 business days, depending on the courier you choose.
Delivery Methods
Provide DHL, FedEx, UPS, EMS, SF Express and Registered Airmail International Delivery Service